Flo-coated Gator shield GALVANIZED open web SQUARE TUBE trusses with 55 ksi tensile strength
(Buildings are rated up to 160mph wind loads)
* Gable style truss widths : from 12ft to 50ft built on a 4/12 pitch and designed to set 12ft on center
* Lean-to style truss widths : from 8ft to 24ft built on a 2/12 pitch and designed to set 12ft on center
* Eye brow trusses are built on a 4/12 pitch up to 6ft wide and will attach directly to the side of your building. Typically used over doorways and windows
*6x6 .60 MCA or 8x8 .80 CCA (saltwater) treated post
*2x6 yellow pine purlins set 24" on center
*Galvanized and ceramic coated hardware
*up to (6) 80# concrete bags around each post with 1/2" lags placed 12 inches from the bottom of the post
*26gauge roofing metal either painted or galvanized
Additional upgrades:
Radiant barrier reflective insulation in the roof ( reflects up to 97% of radiant heat )
Enclosed gables
Enclosed walls
Roll up doors
Walk through doors
Windows
Concrete slab
Our trusses have been engineered in house, stamped by a licensed structural engineer. If stamped drawings are needed they will be obtained from the engineer for the permitting process of your project. The owner of Outback Construction, LLC is a licensed Building Contractor in the state of Florida CBC1260382 and can processes all the permit paperwork needed for each job we install.
(Buildings are rated up to 160mph wind loads)
* Gable style truss widths : from 12ft to 50ft built on a 4/12 pitch and designed to set 12ft on center
* Lean-to style truss widths : from 8ft to 24ft built on a 2/12 pitch and designed to set 12ft on center
* Eye brow trusses are built on a 4/12 pitch up to 6ft wide and will attach directly to the side of your building. Typically used over doorways and windows
*6x6 .60 MCA or 8x8 .80 CCA (saltwater) treated post
*2x6 yellow pine purlins set 24" on center
*Galvanized and ceramic coated hardware
*up to (6) 80# concrete bags around each post with 1/2" lags placed 12 inches from the bottom of the post
*26gauge roofing metal either painted or galvanized
Additional upgrades:
Radiant barrier reflective insulation in the roof ( reflects up to 97% of radiant heat )
Enclosed gables
Enclosed walls
Roll up doors
Walk through doors
Windows
Concrete slab
Our trusses have been engineered in house, stamped by a licensed structural engineer. If stamped drawings are needed they will be obtained from the engineer for the permitting process of your project. The owner of Outback Construction, LLC is a licensed Building Contractor in the state of Florida CBC1260382 and can processes all the permit paperwork needed for each job we install.